DSA non-pc process

Project Definition 

  • Contact Poligon engineering
  • Review design intent
  • Begin coordination of structure (size,roof shape/slope, column spacing, etc)
  • Poligon creates preliminary drawings for architect and district to review
  • Poligon provides quote based on preliminary schematic drawings
  • Poligon refines design in response to feedback and working with the rest of the design team (fire suppression, electrical, etc.)
  • Poligon creates submittal (100% CD) drawings for architect and district to review
  • Poligon provides quote based on submittal drawings

DSA Approval

  • Submit full-size drawings to DSA along with rest of project drawings
  • Send any Poligon related DSA comments (SS, FLS, and/or AC)
  • Poligon provides documentation summarizing our responses to present at the back-check appointment
  • Poligon structure receives DSA approval

Purchasing/Shipping

  • Send Poligon copy of DSA approved drawings for specific project (required before placing order)
  • Submit purchase order through local Poligon sales representative (including frame and roof color)
  • Coordinate optimal ship date through local Poligon sales representative
  • Poligon structure arrives on site

Installation/Project Close Out

  • Poligon available to answer questions from inspectors and/or installers
  • Poligon available to provide additional sketches, letters, etc. required to address filed issues (signed and sealed by California SE). Small fees may apply if Poligon not responsible for challenge requiring a solution.
  • Poligon available to assist with DSA project closeout documents as required.